Novia Class B VariCheck FR AVCL
Our Fire Classification B-s1,d0*, variable AVCL suitable for high rise applications
Product Overview
Novia® VariCheck FR is a Class B* flame resistant, variable vapour check barrier for use as an internal Air & Vapour Control Layer (AVCL). The material meets EN 13984 and is CE marked. Novia® VariCheck FR complies to EN 13501-1 Fire Classification B-s1,d0*. Novia® VariCheck FR is suitable for use in insulated wall or roof applications where low moisture vapour resistance is required. Novia® VariCheck FR is a low cost fire rated solution, for use within standard, high rise and high risk constructions where a vapour check membrane is required. Novia® VariCheck FR is a variable vapour check membrane, achieving sd values between 0.4m - 3.2m. The permeability of the membrane varies seasonally with changes to local humidity levels, as the membrane is less permeable in colder months, and more permeable in warmer months. Novia® VariCheck FR product is milky white in colour, except for 150mm overlap lines.
*Valid for substrates with fire class A2-s1,d0 or A1 such as 12mm plasterboard, with no cavity between product and substrate. Product tested to EN 13501-1.
For projects that also require a fire rated breather membrane which complies to EN 13501-1, we offer several fire rated products. See datasheets for more product specific information.
Novia® VariCheck FR can be found on NBS Chorus and NBS Source software packages. Full information can be found for NBS specification with the table below. The links will open a pop up window with full specification information.
Full installation and technical details can be found on the datasheets available for download below.
Key Features
- Roll size: 1.5m x 50m (75m2)
- EN 13501-1 Fire Classification B-s1, d0*
- Suitable for use in high rise applications under relevant sections of Fire Safety: Approved Document B
- CE compliant to EN 13964
- For application that require higher moisture vapour permeability
- Variable sd vapour check membrane
- Minimises interstitial condensation
- Use in conjunction with Novia FR Pro A1 Breather Membrane for a full Class A1 installation
- Use in conjunction with Novia FR Breather Membrane for a full Class B installation
- Use in conjunction with Novia UV Facade FR Breather Membrane for a full Class B installation in open facade applications
- Alternative Product: Light weight, low cost, Class B Fire Rated Solution Novia 500 Gauge FR Virgin Polythene
- Alternative Product: Class B Fire Rated Solution, with enhanced water vapour resistance, Novia VC4000 FR
- Alternative Product: Class A1 Fire Rated AVCL Solution, Novia FlamePro A1 FR
Download Links
Installation Tips
Installation guidelines can be found on the product datasheets using the links to the left. To install the membranes, we recommend using the Novia double tape system.
Our Novia® Double-Sided Butyl Tape is used on the laps and edges of the membrane, with one of our Novia® Single-Sided Lap Tapes (SSLT) used to complete the lap seal. For fire rated AVCL membranes, we offer our 96mm width, Class B-s1,d0 Novia® FR Aluminium Foil Tape. For difficult areas to seal with tapes, or for additional support in certain applications, Novia® AirSeal 310 FR is available.